This is a demo store. No orders will be fulfilled.

Compact Valve 10 mm

Loading...
Shop By
Now Shopping by
  1. Protective Circuit Schutzbeschaltung mit LED Remove This Item
  2. Orientation of the electr./pneum. Interface gegenüberliegend (GÜ) Remove This Item
  3. System affiliation System 3-10 Remove This Item
  4. pneumatic operating mode 3/2 NC Remove This Item
Shopping Options
Sheathing material solenoid coil
Average power-on time
Overall Width
leakage max.
1. Kind of Current
Medium quality according to ISO standard
Orifice Size Exhaust
Orifice Size Inlet
Permissible operating temperature max.

Compact Valve 10 mm

The type System 3–10 stands for a compact solenoid valve with a width of 10 mm (block assembly is possible). Each variation has an armature diameter of 3 mm, which has been determined as the optimum for this pneumatic class through simulation and practical
testing.

Application of System 3-10

Usually, the solenoids are used in automation as 3/2 way valves or 2/2 way valves with the switching functions normally closed (NC) or normally open (NO). Typical maximum operating pressure and nominal orifice for the 3/2 way model are 10 bar/0.7 mm.

This type has been designed for the use with filtered compressed air and inert gases.

The use of other substances, especially in medical applications, requires prior agreement with nass magnet.

Function

The plunger(1) of System 3–10 is pressed downwards by the reset spring (2). The plunger itself does not feature any sealing elements. The plunger movement transfers to the actuator, which is gathering the sealing element (3). In the de-energized state, the reset spring is taking effect on the sealing element through the armature and the actuator. The sealing element is pushed on the lower valve seat (4). The plunger will move once the solenoid coil is under current. The actuator is now unloaded and moves upwards, supported by the lower pressure spring (5). The sealing element exposes the lower valve seat and seals towards the upper valve seat (6).

In a 2/2 way model or for the NO switching function, the valve seats are charged with individual pressures. In this case, a modified spring design is provided by the manufacturer.

Note: The picture shows the 3/2 way NC type with electric/pneumatic interface on opposite side (OPS).

Shop By
Now Shopping by
  1. Protective Circuit Schutzbeschaltung mit LED Remove This Item
  2. Orientation of the electr./pneum. Interface gegenüberliegend (GÜ) Remove This Item
  3. System affiliation System 3-10 Remove This Item
  4. pneumatic operating mode 3/2 NC Remove This Item
Shopping Options
Sheathing material solenoid coil
Average power-on time
Overall Width
leakage max.
1. Kind of Current
Medium quality according to ISO standard
Orifice Size Exhaust
Orifice Size Inlet
Permissible operating temperature max.
View as Grid Catalog

9 Items

Set Descending Direction
per page
default

Get a quote